48T
$299.00
96T
$399.00
Species:
Mouse
Alternative Name:
C-X-C motif chemokine 15,Chemokine (C-X-C motif) ligand 15,Cxcl15,CXL15,Il8,Lungkine,Scyb15,Small inducible cytokine B15,Small inducible cytokine subfamily B member 15,Small-inducible cytokine B15,weche
Uniport ID:
Q9WVL7
Assay Type:
Sandwich
unit:
pg/mL
Standard:
5000pg/mL
Sensitivity:
46.88 pg/mL
Detection Range:
78.13-5000pg/mL
Assay Time:
3.5H
Sample Type:
Serum, Plasma, Tissue homogenate and Other biological samples;Sample Volume=100μL
Research:
Signal transduction;Metabolic pathway;Tumor immunity;Infection immunity;Developmental science;
Test Principle:
This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Mouse CXCL15. Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse CXCL15 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse CXCL15, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Mouse CXCL15.You can calculate the concentration of Mouse CXCL15 in the samples by comparing the OD of the samples to the standard curve.
| pg/mL | OD | Corrected |
|---|---|---|
| 5000 | 2.479 | 2.435 |
| 2500 | 1.623 | 1.579 |
| 1250 | 0.957 | 0.913 |
| 625 | 0.438 | 0.394 |
| 312.5 | 0.229 | 0.185 |
| 156.25 | 0.131 | 0.087 |
| 78.13 | 0.079 | 0.035 |
| 0 | 0.044 | 0 |
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.
| Intra-assay Precision | Inter-assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 20 | 20 | 20 | 20 | 20 | 20 |
| Mean(ng/mL) | 86.16 | 760.59 | 2346.03 | 112.78 | 838 | 1981.61 |
| Standard deviation | 6.29 | 61.55 | 102.11 | 6.8 | 36.93 | 100.58 |
| C V (%) | 5.41 | 2.89 | 6.22 | 4.69 | 7 | 7.69 |
| Sample Type | Range(%) | Average Recovery(%) |
|---|---|---|
| Serum (n=8) | 80-95 | 87 |
| EDTA plasma (n=8) | 92-105 | 98 |
| Cell culture media (n=8) | 84-96 | 90 |
| Serum (n=5) | EDTA plasma (n=5) | Cell culture media (n=5) | ||
|---|---|---|---|---|
| 1:2 | Range (%) | 95-103 | 98-103 | 85-94 |
| Average (%) | 98 | 100 | 87 | |
| 1:4 | Range (%) | 89-101 | 86-92 | 97-106 |
| Average (%) | 93 | 87 | 98 | |
| 1:8 | Range (%) | 87-98 | 87-93 | 92-101 |
| Average (%) | 94 | 91 | 96 | |
| 1:16 | Range (%) | 85-92 | 93-102 | 82-90 |
| Average (%) | 85 | 100 | 88 |